Reference Guide
PCIe slot 04 PCIE.ChassisSlot.4
PCIe slot 05 PCIE.ChassisSlot.5
PCIe slot 06 PCIE.ChassisSlot.6
PCIe slot 07 PCIE.ChassisSlot.7
PCIe slot 08 PCIE.ChassisSlot.8
<PCIe Slot#> <Virtual Adapter#> <FQDD>
PCIe slot 09 Virtual Adapter 01 RAID.ChassisIntegrated.
1-1-1
PCIe slot 09 Virtual Adapter 02 RAID.ChassisIntegrated.
1-1-2
PCIe slot 09 Virtual Adapter 03 RAID.ChassisIntegrated.
1-1-3
PCIe slot 09 Virtual Adapter 04 RAID.ChassisIntegrated.
1-1-4
PCIe slot 10 Virtual Adapter 01 RAID.ChassisIntegrated.
2-1-1
PCIe slot 10 Virtual Adapter 02 RAID.ChassisIntegrated.
2-1-2
PCIe slot 10 Virtual Adapter 03 RAID.ChassisIntegrated.
2-1-3
PCIe slot 10 Virtual Adapter 04 RAID.ChassisIntegrated.
2-1-4
• Displays the properties of a PCIe slot selected using FQDD:
racadm getpciecfg -c pcie.chassisslot.1
• Displays the properties of a Virtual Adapter selected using FQDD:
racadm getpciecfg -c RAID.ChassisIntegrated.2-1-4
• Displays the ride-through properties of the system
racadm getpciecfg -r
Ride-through mode is enabled
Ride-through timeout 1800 secs
getpminfo
Description Displays power management status information.
To use this subcommand, you must have CMC
Login User privilege.
Synopsis
racadm getpminfo
Example
racadm getpminfo
[Real-Time Power Statistics]
System Input Power = 600
W (188 BTU/hr)
Peak System Power = 600
W (188 BTU/hr
Peak System Power Start Time =
16:02:10 01/16/2008
Peak System Power Timestamp =
06:32:55 01/26/2009
Minimum System Power = 400
W (177 BTU/hr)
Minimum System Power Start Time =
55