Reference Guide

getled
Description Displays the LED settings on a module: blinking,
not blinking, or unknown (for empty slots).
To use this subcommand, you must have the Login
User privilege.
Synopsis
racadm getled -m <module>
Input CMC only options:
-m <module> — Specifies the module whose LED
settings you want to view.
<module> can be one of the following:
server-n where n=1–4
switch-n where n=1
chassis
cmc-active
Example For CMC:
racadm getled -m server-10
<module> <LED state> server-10 Blinking
racadm getled -m chassis
<module> <LED state> server-10 Not blinking
racadm getled -m server-1
<module> <LED state> server-1 ON
racadm getled -m server-9
<module> <LED state> server-9 Extension(1)
getmacaddress
Description Displays the MAC/WWN addresses and fabric ID decoder for all modules or for a
specified module.
The decoder values indicate the protocols of the network cards:
0— Unsupported
1— ISCSI
2— FCoE-FIP
3— iSCSI/FCoE-FIP
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getmacaddress
racadm getmacaddress -m chassis
racadm getmacaddress -m switch-<n>
42