Reference Guide

getdcinfo
Description Displays general I/O module and daughter card configuration information.
Only the CMC controls daughtercards.
To use this subcommand, you must have the CMC Login User privilege.
NOTE: Fabric verification for server DCs is performed only when the
chassis is turned on. When the chassis is on stand-by power, iDRACs
on the server modules remain turned off and thus are unable to report
the server's DC fabric type. The DC fabric type may not be reported in
the CMC user interface until iDRAC on the server is turned on.
Synopsis
racadm getdcinfo
Input -n — Displays the model names for the daughter cards in servers.
Example
The following example is for a system with multi-slot servers.
racadm getdcinfo
Group A I/O Type : Gigabit Ethernet
Group B I/O Type : PCIe
Group C I/O Type : PCIe
<IO#> <Type> <State> <Role>
switch-1 Gigabit Ethernet OK Master
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>
server-1 Present PCIe OK PCIe OK
server-2 Not Present None N/A None N/A
server-3 Present PCIe OK None N/A
server-4 Not Present None N/A None N/A
getdcinfo -n
<Server#> <Presence> <DC1 Model Name> <DC2 Model Name>
server-1 Present None None
server-2 Not Present None None
server-3 Not Present None None
server-4 Present None Broadcom M5708t
39