Reference Guide
# cfgCurrentIPv6Address1=2009:123::e48f:9dd8:6f51:a669/64
# cfgCurrentIPv6Address2=fd88:1::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Address3=fd88:2::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Gateway=fe80::21c:23ff:fe77:6215
# cfgCurrentIPv6DNSServersFromDHCP6=1
# cfgCurrentIPv6DNSServer1=2009:123::1
# cfgCurrentIPv6DNSServer2=::
cfgNetTuning
This group enables users to configure the advanced network interface parameters for the RAC NIC or
CMC. When configured, the updated settings may take up to a minute to become active.
The following sections provide information about the objects in the cfgNetTuning group.
CAUTION: Use extra precaution when modifying properties in this group. Inappropriate
modification of the properties in this group can result in your RAC NIC become inoperable.
cfgNetTuningNicSpeed
Description Specifies the speed for the CMC NIC. This property
is used only if cfgNetTuningNicAutoNeg is set to
0.
Legal Values 10, 100, or 1000
Default 100
cfgNetTuningNicFullDuplex (Read/Write)
Description Specifies the duplex setting for the RAC or CMC
NIC. This property is used only if the
cfgNetTuningNicAutoNeg is set to 0 (disabled).
Legal Values
• 0 (Half Duplex)
• 1 (Full Duplex)
Default 1
cfgNetTuningNicMtu (Read/Write)
Description The size in bytes of the maximum transmission unit
used by CMC NIC.
Legal Values 576 – 1500
Default 1500
NOTE: IPv6 requires a minimum MTU of 1280. If IPv6 is enabled, and cfgNetTuningMtu is set to a
lower value, the CMC uses an MTU of 1280.
179