Reference Guide
cfgChassisPowerButtonEnable=1
cfgChassisAllow110VACOperation=0
cfgChassisMaxPowerConservationMode=0
cfgChassisPerformanceOverRedundancy=1
# cfgSystemEnergyConsumptionClear = ****(Write-Only)
cfgChassisServerBasedPowerMgmtMode=0
• racadm config -g cfgChassisPower ‑o cfgChassisPowerClear 1
Clears cfgChassisMinPower and cfgChassisPeakPower.
cfgChassisServerBasedPowerMgmtMode
Description Indicates the server-based power management mode of a chassis.
Legal Values
• 0 (disabled)
• 1 (enabled)
Default 0 (disabled)
cfgChassisPowerCapBTU (Read/Write)
Description Indicates the maximum power consumption limit
(in BTU/hr) for the entire chassis. The command
generates an error if server throttling is necessary
to achieve the power goal based on the value for
this setting.
Legal Values 9264 - 56931 BTU/hr
Default 43221 BTU/hr
cfgKVMInfo
This group is used to view the mapping information for the KVM.
Use this object with the config or getconfig subcommands.
To use this object property, you must have Chassis Configuration Administrator privilege.
cfgKvmMapping Read or Write
Description Maps the slots to the KVM.
Legal Values 1, 2, 3, and 4 are the slot numbers that are specified.
Default 1
cfgKvmSlot<num>Enable Read or Write
Description Enable the slots (1 to 4) to access using KVM:
• cfgKvmSlot1Enable
• cfgKvmSlot2Enable
169