Reference Guide
NOTE: If the specified percent is lower than
the minimum value, the CMC will set the value
to the minimum value.
Default 100
cfgChassisRedundancyPolicy (Read/Write)
Description Sets the redundancy policy of the chassis.
Legal Values
• 0 (no redundancy)
• 1 (AC redundancy)
• 2 (power supply redundancy)
Default 0 (no redundancy)
cfgChassisDynamicPSUEngagementEnable (Read/Write)
Description Enables or disables dynamic engagement.
Legal Values
• 0 (disabled)
• 1 (enabled)
Default 0 (disabled)
cfgChassisInMaxPowerCapacity (Read Only)
Description Indicates the total chassis power budget (in watts) available for chassis
operation.
Legal Values None
Default None
cfgChassisInRedundancyReserve (Read Only)
Description Indicates the amount of redundant power (in Watt) in reserve that can be
utilized in the event of an AC grid or PSU failure. This value is 0 if the
Redundancy Policy is set to 0 (no redundancy).
Legal Values 0 (disabled)
1 (enabled)
Default None
166