Reference Guide
cfgRacTuneHttpsPort=443
cfgRacTuneTelnetPort=23
cfgRacTuneSshPort=22
cfgRacTuneIpRangeEnable=0
cfgRacTuneIpRangeAddr=192.168.1.1
cfgRacTuneIpRangeMask=255.255.255.0
cfgRacTuneIpBlkEnable=0
cfgRacTuneIpBlkFailCount=5
cfgRacTuneIpBlkFailWindow=60
cfgRacTuneIpBlkPenaltyTime=300
# cfgRacTuneTimezoneOffset=-18000
# cfgRacTuneDaylightOffset=3600
cfgRacTuneTimezoneOffset (Read Only)
Description Specifies the time zone offset (in minutes) from Greenwich Mean Time (GMT)/
Coordinated Universal Time (UTC) to use for the RAC Time. Some common time zone
offsets for time zones in the United States are:
• –480 (PST—Pacific Standard Time)
• –420 (MST—Mountain Standard Time)
• –360 (CST—Central Standard Time)
• –300 (EST—Eastern Standard Time)
For CMC: This object property is read only. Specifies the difference in number of
seconds, from the UTC/GMT. This value is negative if the current time zone is west of
Greenwich.
Legal Values –720 to 7800
Default 0
Example
racadm getconfig -g cfgRacTuning
cfgRacTuneRemoteRacadmEnable=1
cfgRacTuneWebserverEnable=1
cfgRacTuneHttpPort=80
cfgRacTuneHttpsPort=443
cfgRacTuneTelnetPort=23
cfgRacTuneSshPort=22
cfgRacTuneIpRangeEnable=0
cfgRacTuneIpRangeAddr=192.168.1.1
cfgRacTuneIpRangeMask=255.255.255.0
cfgRacTuneIpBlkEnable=0
cfgRacTuneIpBlkFailCount=5
cfgRacTuneIpBlkFailWindow=60
cfgRacTuneIpBlkPenaltyTime=300
# cfgRacTuneTimezoneOffset=-18000
# cfgRacTuneDaylightOffset=3600
cfgRacTuneWebserverEnable (Read/Write)
Description Enables or disables the Web server. If this property
is disabled, CMC is not accessible using client Web
141