Users Guide

Conguring power button
To congure the chassis power button:
1 In the left pane, click Chassis Overview > Front Panel > Setup.
2 On the Front Panel Conguration page, under the Power Button Conguration section, select the Disable Chassis Power Button
option, and then click Apply.
The chassis power button is disabled.
Accessing a server using KVM
To map a Server to KVM from web interface:
1 Connect a monitor to the video connector and a keyboard to USB connector located on the front of the chassis.
2 In the left pane, click Chassis Overview > Front Panel > Setup.
3 On the Front Panel Conguration page, under the KVM Conguration section, select Enable KVM Mapping option.
4 On the Front Panel Conguration page, under the KVM Conguration section, for KVM Mapped option, select the desired server
from the drop down list.
5 Click Apply.
To map a Server to KVM using racadm, useracadm config -g cfgKVMInfo -o cfgKvmMapping [server slot #]
command.
To view the current KVM mapping using racadm, use racadm getconfig -g cfgKVMInfo.
Conguring chassis management at server mode
This feature allows you to manage and monitor the chassis shared components and chassis nodes as rack servers. When this feature is
enabled, you can use the iDRAC RACADM proxy, blade server operating systems and Lifecycle Controller to do the following:
Monitor and manage chassis fans, power supplies, temperature sensors
Update and congure the CMC rmware
Conguring chassis management at server using CMC web
interface
To enable chassis management at server mode:
1 In the left pane, click Chassis Overview > Setup > General.
2 In the General Chassis Settings page, from the Chassis Management at Server Mode drop-down, select one of the following
modes:
None — This mode does not enable you to monitor or manage the chassis component through iDRAC, OS, or Lifecycle Controller.
Monitor — This mode enables you to monitor the chassis components but you cannot perform any rmware update through
iDRAC, OS, iDRAC RACADM proxy, or Lifecycle Controller.
Manage and Monitor — This mode enables you to monitor the chassis components and update the CMC rmware using DUP
through iDRAC, OS, iDRAC RACADM, or Lifecycle Controller.
Installing and setting up CMC
35