Users Guide

Conguring storage sleds in joined mode
In joined mode, the RAID controllers are mapped to a single compute sled. However, only one controller is enabled and all the disk drives are
connected to it.
Conguring storage sleds using CMC web interface
1 In the left pane, click Chassis Overview > Server Overview and click a storage sled.
The details of the storage sled are displayed.
2 In the menu on the right side, click Setup.
The Storage Conguration page is displayed.
You can also access the Storage Conguration page by selecting a storage sled on the Chassis Health page. Under Quick Links, click
Storage Array Setup.
3 Under Components, select one of the following options:
Split Dual Host
Split Single Host
Joined
NOTE: Power o the compute sled before conguring the storage sled. Click Server Power Control at the top of the page
to power o the compute sled. For more information, see the Online Help.
4 Click Apply.
Conguring storage sleds using RACADM
You can connect storage sleds with compute sleds using the config or getconfig RACADM command with the cfgStorageModule
option. For more information, see the getstoragemoduleinfo section in the Chassis Management Controller for PowerEdge FX2/FX2s
RACADM Command Line Reference Guide available at dell.com/support/manuals.
Managing storage sleds using iDRAC RACADM proxy
The iDRAC RACADM proxy feature enables you to manage storage sleds in the FX2s chassis through iDRAC RACADM, when CMC is not
in the network.
To access iDRAC locally, use the following command:
racadm <command> --proxy
Example: racadm getractime --proxy
You can also access the iDRAC RACADM remotely. For more information, see the section, “RACADM Proxy, in the Integrated Dell Remote
Access Controller 8 (iDRAC8) Version 2.10.10.10 RACADM Command Line Interface Reference Guide.
NOTE
: Only local and remote RACADM proxies are supported in this release.
Viewing storage array status
In the left pane, click Chassis Overview > Server Overview > <storage sled>. The Storage Array Status page is displayed in the right
pane. You can also access the Storage Array Status page from the Chassis Health page.
1 On the Chassis Health page, click a storage sled on the front panel image.
The details of the storage sled are displayed at the bottom of the right pane.
2 Under Quick Links, click Storage Array Status.
Conguring