Users Guide
Conguring storage sleds
Half-width storage sleds that are used in the FX2s chassis contain the following:
• One or two RAID controllers
• Maximum of 16 disk drives
You can congure individual storage sleds containing two RAID controllers to operate in the following modes:
• Split-single
• Split-dual
• Joined
NOTE: Do not insert a storage sled in slot 1 of the chassis as it is not a valid location for storage sleds.
NOTE: This section is applicable only to dual-controller storage modules.
NOTE: You can also congure and monitor storage sleds using the iDRAC Comprehensive Embedded Management (CEM). For
more information, see the
Integrated Dell Remote Access Controller (iDRAC) User’s Guide
.
Topics:
• Conguring storage sleds in split-single mode
• Conguring storage sleds in split-dual mode
• Conguring storage sleds in joined mode
• Conguring storage sleds using CMC web interface
• Conguring storage sleds using RACADM
• Managing storage sleds using iDRAC RACADM proxy
• Viewing storage array status
Conguring storage sleds in split-single mode
In split-single mode, the two RAID controllers are mapped to a single compute sled. Both the controllers are enabled and each controller is
connected to eight disk drives.
Conguring storage sleds in split-dual mode
In split-dual mode, both RAID controllers in a storage sled are connected to two compute sleds.
If a storage sled is located below a full-width PowerEdge FC830 sled, it can be congured in the split-dual mode. But the controllers are
connected to a single compute sled and only that compute sled is reported.
If a storage sled is congured in the split dual mode and is in a location where it cannot be connected to two compute sleds, then the
second controller is not connected to any compute sled.
You must have the Chassis Conguration Administrator privilege and power o the compute sled before changing the setting.
8
102 Conguring storage sleds