Release Notes

Known Issues
Issue 1:
Description
PCIe card device name displayed on the iDRAC GUI and CMC GUI are not same for Broadcom/Qlogic 10G card.
Resolution
Refer to the iDRAC GUI, it is accurate and current.
Versions/Systems Aected
None
Issue 2:
Description
An error occurs while importing CMC conguration le using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the conguration le. Enable or disable IPv6 using the command, racadm
config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0
.
Versions/Systems Aected
CMC for PowerEdge FX2 1.10 or later
Issue 3:
Description
The value of "Power Available for Server Power-on” can increase after PSU failure and recovery, without any changes to the underlying
chassis hardware components.
Resolution
For actual power consumption of the chassis, in the CMC GUI, navigate to the Chassis Overview > Power > Power Monitoring >
System Input Power page.
Versions/Systems Aected
All the versions of FX2/FXs
8
14 Known Issues