CLI Guide
Example
racadm racdump
===============================================================================
General System/RAC Information
===============================================================================
CMC Information:
CMC Date/Time = Mon Jul 04 2016 18:50
Primary CMC Location = CMC
Primary CMC Version = 2.00
Last Firmware Update = Mon Jul 03 2016 20:06
Hardware Version = A00
CMC Network Information:
NIC Enabled = 1
MAC Address = F8:BC:12:32:E6:80
Register DNS CMC Name = 0
DNS CMC Name = cmc-grapple
Current DNS Domain = SSEFW.COM
VLAN ID = 1
VLAN Priority = 0
VLAN Enabled = 0
CMC IPv4 Information:
IPv4 Enabled = 1
Current IP Address = 10.94.224.187
Current IP Gateway = 10.94.224.1
Current IP Netmask = 255.255.255.0
DHCP Enabled = 1
Current DNS Server 1 = 10.116.2.250
Current DNS Server 2 = 10.116.2.251
DNS Servers from DHCP = 1
CMC IPv6 Information:
IPv6 Enabled = 0
Autoconfiguration Enabled = 1
Link Local Address = ::
Current IPv6 Address 1 = ::
Current IPv6 Gateway = ::
Current IPv6 DNS Server 1 = ::
Current IPv6 DNS Server 2 = ::
DNS Servers from DHCPv6 = 1
Chassis Information:
System Model = PowerEdge FX2s
System AssetTag = 00000
Service Tag = grapple
Express Service Code = 108126335602
Chassis Name = CMC-grapple
Chassis Location = [UNDEFINED]
Chassis Midplane Version = 1.0
Power Status = ON
System ID = 1488
PCIe Switch Board Type = Gen 3
===============================================================================
Session Information
===============================================================================
SSNID Type User IP Address Login Date/Time
49580 SSH root 10.94.78.51 07/04/2016 18:07:40
===============================================================================
Sensor Information
===============================================================================
<senType> <Num> <sensorName> <status> <reading> <units> <LC>
<UC> <PWM>
FanSpeed 1A Fan-1A OK 8040 rpm 3720
RACADM Subcommand Details
69