CLI Guide
server-3c 2.30.30.30 (10) PowerEdge FC430
iDRAC8 Y
server-3d 2.10.10.10 (49) PowerEdge FC430
iDRAC8 Y
<Switch> <Model Name> <HW Version>
<FW Version>
switch-1 1GBE PASS-THROUGH MODULE A00 N/A
<CMC> <CMC
Version> <Updatable>
cmc
2.00.000.20161003sahu Y
<Chassis Infrastructure> <FW Version> <FQDD>
Main Board 1.20.A00.201502058
System.Chassis.
1#Infra
structure.1
• -b — Displays the server's current BIOS version (default is iDRAC version).
• -c — Displays the server's current CPLD version.
• -l — Displays the rmware versions Lifecycle Controller components.
• -f < lter > — Filters the components. Must be used with -1 and be one of the following values:
– bios: BIOS
– idrac: iDRAC
– usc: Unied Server Congurator (Lifecycle Controller)
– diag: 32-bit Diagnostics
– drivers: OS Driver Package
– nic-x: Network Interface card. See -l output for possible values of x.
• -m < module > — Species the module or device for which you must retrieve the version
information.
< module > is one of the following:
– server-n , where n = 1 to 4.
– switch-n , where n = 1 to 2.
– CMC
– mainboard
Example
• Retrieve the version for a server 4
racadm getversion -m server-4
• Retrieve the Lifecycle Controller component versions for servers 1 and 3:
racadm getversion -l -m server-1 -m server-3
• Retrieve the Lifecycle Controller BIOS versions for servers 1 and 3:
racadm getversion -l -m server-1 -m server-3 -f bios
• Retrieve the version for all modules:
racadm getversion
• Retrieve the iDRAC version in all the servers that are attached to the chassis:
racadm getversion -f idrac
ifcong
Table 75. Details of
ifcong
Description Displays the contents of the network interface table.
62 RACADM Subcommand Details