CLI Guide
NOTE: When Management Port 2 is set for Redundant but is cabled for Stacking, the downstream CMCs (further from the top-
of-rack switch) will not have a network link.
NOTE: When Management Port 2 is set for Stacking but is cabled for Redundant (two connections to the TOR switch), routing
loops could cause a network storm.
cfgRacSecurity
This group is used to congure settings related to CMC SSL certicate signing request (CSR) feature. The properties in this group must be
congured before generating a CSR from CMC.
Use this object with the cong or getcong subcommands.
To use this object property, you must have Chassis Conguration Administrator privilege.
For more information on generating certicate signing requests, see the subcommand "sslcsrgen."
The following sections provide information about the objects in the cfgRacSecurity group.
cfgRacSecCsrCommonName (Read/Write)
Table 324. Details of cfgRacSecCsrCommonName
Description Species the CSR Common Name (CN) that must be an IP or CMC name as given in the certicate.
Legal Values A string of up to 254 characters.
Default <blank>
cfgRacSecCsrOrganizationName (Read/Write)
Table 325. Details of cfgRacSecCsrOrganizationName
Description Species the CSR Organization Name (O).
Legal Values A string of up to 254 characters.
Default <blank>
cfgRacSecCsrOrganizationUnit (Read/Write)
Table 326. Details of cfgRacSecCsrOrganizationUnit
Description Species the CSR Organization Unit (OU).
Legal Values A string of up to 254 characters.
Default <blank>
CMC Property Database Group and Object Descriptions 161