CLI Guide

cfgKvmMapping
Table 289. Details of cfgKvmMapping
Description Selects the server to which the KVM connects
Legal Values
1[a-d]-4[a-d]
Default 0 (Unmapped)
cfgAlerting
This group enables or disables SNMP event trap alerting and sets the event lter.
Use this object with the cong or getcong subcommands.
cfgAlertingEnable
Table 290. Details of cfgAlertingEnable
Description Enables or disables event traps on the CMC.
Legal Values
1 (true)
0 (false)
Default None
To use this object property, you must have the Chassis Conguration Administrator privilege.
cfgAlertingSourceEmailName
Table 291. Details of cfgAlertingSourceEmailName
Description Species the e-mail address used to send e-mail notications when an event occurs.
Legal Values None
Default None
CMC Property Database Group and Object Descriptions 151