Using the RACADM Command Line Interface 87
Disabling a CMC User
Using RACADM, you can only disable CMC users manually and on an
individual basis. You cannot delete users by using a configuration file.
The following example illustrates the command syntax that can be used to
delete a CMC user:
racadm config -g cfgUserAdmin -i 2
cfgUserAdminPrivilege 0x0
Configuring SNMP and E-mail Alerting
You can configure the CMC to send SNMP event traps and/or e-mail alerts
when certain events occur on the chassis. For more information and
instructions, see "Configuring SNMP Alerts" and "Configuring E-mail Alerts."
You can specify the trap destinations as appropriately-formatted
numeric addresses (IPv6 or IPv4), or fully-qualified domain names (FQDNs).
Choose a format that is consistent with your networking
technology/infrastructure.
NOTE: The Test TRAP functionality does not detect improper choices based
on current network configuration. For example, using an IPv6 destination in an
IPv4-only environment.
Configuring Multiple CMCs in Multiple Chassis
Using RACADM, you can configure one or more CMCs with identical
properties.
When you query a specific CMC card using its group ID and object ID,
RACADM creates the racadm.cfg configuration file from the retrieved
information. By exporting the file to one or more CMCs, you can configure
your controllers with identical properties in a minimal amount of time.
NOTE: Some configuration files contain unique CMC information (such as the static
IP address) that must be modified before you export the file to other CMCs.