User's Manual
Troubleshooting and Recovery 335
b
Enter the desired originator e-mail for the alert, or leave it blank to
use the default e-mail originator. The default is cmc@[IP_address]
where [IP_address] is the IP address of the CMC. If you choose to
enter a value, the syntax of the e-mail name is emailname[@domain],
and an e-mail domain can be optionally specified. If @domain is not
specified and there is an active CMC network domain, then the e-mail
address of emailname@cmc.domain is used as the source e-mail.
If @domain is not specified and CMC has no active network domain,
then the IP address of the CMC is used (for example,
emailname@[IP_address]).
c
Click
Apply
to save your changes.
7
Specify the e-mail address(es) that will receive the alerts:
a
Type a valid e-mail address in an empty
Destination Email
Address
field.
b
Enter an optional
Name
. This is the name of the entity receiving the
e-mail. If a name is entered for an invalid e-mail address, it is ignored.
c
Click
Apply
to save your settings.
To send a test e-mail to an e-mail alert destination:
1
Log in to the CMC Web interface.
2
Select
Chassis
in the system tree.
3
Click the
Alert Management
tab. The
Chassis Events
page appears.
4
Click the
Email Alert Settings
sub-tab. The
Email Alert Destinations
page displays.
5
Click
Send
in the
Destination Email Address
column beside the
destination.
Using RACADM
1
Open a serial/Telnet/SSH text console to the CMC and log in.
2
Enable alerting by typing:
racadm config -g cfgAlerting -o cfgAlertingEnable 1
NOTE: Only one filter mask may be set by both SNMP and e-mail alerting.
You may skip step 3 if you have already set a filter mask.