User's Manual

284 Power Management
Using RACADM
Open a serial/Telnet/SSH text console to the CMC, log in, and type:
racadm chassisaction -m chassis <
action
>
where
<
action
> is
powerup, powerdown, powercycle,
nongraceshutdown or reset.
Executing Power Control Operations on an IOM
You can remotely execute a reset or power cycle on an individual IOM.
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
Using the Web Interface
1
Log in to the CMC Web interface.
2
Select
I/O Modules
. The
I/O Modules Status
page displays.
3
Click the
Power Management
tab. The
Power Control
page displays.
4
Select the operation you want to execute (
reset
or
power cycle
) from the
drop-down menu beside the IOM in the list.
5
Click
Apply
. A dialog box appears requesting confirmation.
6
Click
OK
to perform the power management action (for example,
cause the IOM to power cycle).
Using RACADM
Open a serial/Telnet/SSH text console to the CMC, log in, and type:
racadm chassisaction -m switch-<
n
> <
action
>
where
<
n
> is a number 1-6 and specifies the IOM (A1, A2, B1, B2, C1, C2),
and
<
action
> indicates the operation you want to execute:
powercycle
or
reset
.
Executing Power Control Operations on a Server
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
The CMC enables you to remotely perform several power management actions,
for example, an orderly shutdown, on an individual server in the chassis.