User's Manual
Power Management 265
Table 8-6. Power Supply Health Status Information
Item Description
Name Displays the name of the power supply unit: PS-[n], where [n] is
the power supply number.
Present Indicates whether the PSU is Present or Absent.
Health OK Indicates that the PSU is present and
communicating with the CMC. In the event of
a communication failure between the CMC
and the power supply, the CMC cannot obtain
or display health status for the PSU.
Warning Indicates that only Warning alerts have been
issued, and corrective action must be taken.
If corrective actions are not taken within the
administrator-specified time, it could lead to
critical or severe power failures that can affect
the integrity of the chassis.
Severe Indicates at least one Failure alert has been
issued for the power supply. Severe status
indicates a power failure on the chassis, and
corrective action must be taken immediately.
Power Status Indicates the power state of the power supplies (one of the
following): Initializing, Online, Stand By, In Diagnostics, Failed,
Offline, Unknown, or Absent.
Capacity Displays the power supply’s capacity in watts.
Table 8-7. System Power Health Status Information
Item Description
Overall Power
Health
Indicates the health status (OK, Non-Critical, Critical,
Non-Recoverable, Other, Unknown) of the power management
for the entire chassis.
System Power
Status
Displays the power status (On, Off, Powering On, Powering
Off) of the chassis.
Redundancy Indicates the power supply redundancy status. Values include:
No: Power Supplies are not redundant.
Yes: Full Redundancy in effect.