User's Manual

168 Using the CMC Web Interface
When the update is complete, the new firmware is displayed on the
Updatable Components page and the updated system will no longer be
present on that page.
Updating the Server iDRAC Firmware
NOTE: The iDRAC (on a Server) will reset and become temporarily unavailable
after firmware updates have been uploaded successfully.
NOTE: The iDRAC firmware must be at version 1.4 or greater for servers
with iDRAC, or 2.0 or greater for servers with iDRAC6 Enterprise.
1
Log back in to the CMC Web interface.
2
Select
Chassis
in the system tree.
3
Click the
Update
tab. The
Updatable Components
page appears.
4
Select the iDRAC or iDRACs to update by selecting the
Update Targets
check box those devices.
5
Click the
Apply iDRAC Update
button below the iDRAC component list.
6
In the
Firmware Image
field, enter the path to the firmware image file on
your management station or shared network, or click
Browse
to navigate to
the file location.
7
Click
Begin Firmware Update
. The
Firmware Update Progress
section
provides firmware update status information. A status indicator displays
on the page while the image file uploads. File transfer time can vary greatly
based on connection speed. When the internal update process begins,
the page automatically refreshes and the firmware update timer displays.
Additional items to note:
Do not use the
Refresh
button or navigate to another page during
the file transfer.
To cancel the process, click
Cancel File Transfer and Update
- this
option is available only during file transfer.
Update status displays in the
Update State
field; this field is
automatically updated during the file transfer process.
NOTE: The update may take several minutes for the CMC or server.