User's Manual
120 Using the CMC Web Interface
Table 5-12 provides descriptions of the information provided on the
Temperature Sensors Information page.
Table 5-12. Temperature Sensors Health Status Information
Item Description
ID Displays the numeric ID of the temperature probe.
Name Displays the name of each temperature probe on the chassis,
servers, IOMs, and iKVM. Examples: Ambient Temp,
Server 1 Temp, I/O Module 1, iKVM Temp.
Present Indicates whether the sensor is present (Yes) or absent (No) in the
chassis.
Health OK Indicates that the temperature probe unit is
present and communicating with the CMC.
Indicates that the health of the temperature
probe unit is OK.
Severe Indicates that the temperature sensor has a
failure and the health is critical. Corrective
action must be taken immediately.
Unknown Displayed with the chassis is first powered on.
In the event of a communication failure
between the CMC and the temperature probe
unit, the CMC cannot obtain or display health
status for the temperature probe.
Reading Indicates the current temperature in degrees Centigrade and
Fahrenheit.
Threshold
Maximum
Indicates the highest temperature, in degrees Centigrade and
Fahrenheit, at which a Failure alert is issued.
Threshold
Minimum
Indicates the lowest temperature, in degrees Centigrade and
Fahrenheit, at which a Failure alert is issued.