Owner's Manual
file:///T|/htdocs/SOFTWARE/smdrac3/cmc/cmc2_10/en/readme/readme.TXT[10/26/2012 2:25:55 PM]
Allowed values: 10, 100, 1000 (default 1000)
- CMC version 1.20 and later:
Allowed values: 10, 100 (default 100)
* While performing firmware updates on servers located in the
chassis, make sure there is minimal to no activities on the server
(for example, avoid running discovery on the servers through management
applications such as IT Assistant or running IPMI commands). (276448)
* While performing multiple iDRAC firmware updates, the CMC performs
CPU-intensive activities and may not respond or respond
slower for the first couple of minutes. Please refrain from running
additional commands during this period. (281719)
* Updating the firmware on an Infiniband IOM (IOMINF) causes the IOM to
reset at the end of the update procedure. (270706)
* When configuring network settings on the iDRAC using the CMC RACADM commands,
make sure the command executed is completed successfully, before running
another network configuration command. To ensure that the settings are
applied on the target iDRAC, check the current configuration using the
appropriate RACADM command or use the Web GUI. (322063)
* When using the remote RACADM windows client, on a management station with
Internet Explorer version 7.0 or above installed, to capture the existing RACADM configuration
into a file, the command fails due to a timeout issue, without giving a
success or failure message. Manually run the individual commands to capture
cfgServerInfo(for all required indexes), cfgKvmInfo and cfgAlerting groups
and add them to the configuration file.(303086)
* When browsing the Remote File Share page for the servers, some of the blade
servers may indicate in the 'Connect Status' column they are already connected.
The does not necessarily mean a Remote File Share is already in progress on
the blade server. It is possible the blade server may have a 'Virtual Media'
session in progress and in the connected state. In such situations and prior
to proceeding with the Remote File Share operations (Connect/Disconnect/Deploy),
please ensure the existing Virtual Media session on the blade server is not
inadvertently overridden. If this is the intention, then it is possible to
proceed with the Remote File Share operations and override the existing Virtual
Media session on the blade server. Similarly, if an existing Remote File Share
session was already in progress on the blade server, the 'Connect Status' column
would indicate a connected state and it would be possible to override the existing
Remote File Share session.(322091)
* When connecting to a switch with the connect command, an error message
'stty: /dev/ttyS1: unable to perform all requested operations: No such file
or directory' may be displayed. This message does not prevent you from
connecting you to the switch and may be ignored.(325197)
#####################################################################
KNOWN ISSUES FOR USER INTERFACE ONLINE HELP
#####################################################################