stating that the page contains both secure and non-secure items and
will ask if you want to continue. Select "Yes". This is because
Internet Explorer version 6 does not allow the use of hidden IFRAMES
on secure (SSL) pages. (183022)
* In Firefox version 1.5, you must manually refresh pages. Automatic
page updating is not fully supported in this version of the Firefox
browser.
* In Internet Explorer version 6, after updating the active CMC you
may need to close the browser used to login to the CMC before
attempting to login again. (232942)
* When loading or sorting CMC log entries in a Firefox browser, you may get
a pop up warning about an unresponsive script. To prevent these warnings,
perform the following steps:
(a) In the Firefox address bar, enter "about:config".
(b) Scroll down and find the "dom.max_script_run_time" entry.
(c) Double-click that entry and change the value to at
least 30. (248345)
* When using the CMC Web Interface, a popup dialog may appear with the message
“Content from the website listed below is being blocked by the Internet
Explorer Enhanced Security Configuration. https//”.
You can perform one of two actions to prevent this popup dialog:
1. Uncheck the option on popup check box to
“Continue to prompt when website content is blocked” and click Close.
-OR-
2. Enable scripting (Javascript) in the Internet zone.
– From the browser menu, select:
Tools->Internet Options->Security Tab
– Select the “Internet” zone.
– Click the “Custom Level…” button.
– Scroll to “Scripting->Active scripting” section and
click Enable.
– Click the OK button.
Click the OK button. (297730)
######################################################################
KNOWN ISSUES FOR CMC Version 2.10
######################################################################
* CMC firmware 1.2 has enhanced the power allocation algorithms to
allow modular servers to receive higher power allocations. If you
downgrade the CMC to 1.10 or an earlier firmware version, servers with
the new higher power allocations may be powered off because the
earlier firmware cannot support the higher chassis power allocations.
If this occurs, power the server back on. (230143)
* After a CMC reset, the CMC may require up to one minute after the
login prompt is displayed before accepting the RACADM commands .
Commands issued prior to that time may receive an error message. (273716)