User's Manual

94 Using the CMC Web Interface
For information on how to launch the iDRAC management console and
single sign-on policies, see "Launching iDRAC using Single Sign-On" on
page 160.
Editing Slot Names
The Slot Names page allows you to update slot names in the chassis. Slot
names are used to identify individual servers. When choosing slot names, the
following rules apply:
Names may contain
a maximum of 15
printable ASCII characters (ASCII
codes 32 through 126), excluding the double quote (
"
, ASCII 34). If using
the RACADM command to change the slot name using any special
characters, (~!@#$%^&*), the name string must be enclosed in double
quotes for the environment to pass them correctly to the CMC.
Slot names must be unique within the chassis. No two slots may have the
same name.
Strings are not case-sensitive.
Server-1
,
server-1
, and
SERVER-1
are equivalent names.
Slot names must not begin with the following strings:
Switch-
Fan-
PS-
KVM
DRAC-
MC-
Chassis
Housing-Left
Housing-Right
Service Tag Displays the service tag for the server. The service tag is a unique
identifier provided by the manufacturer for support and maintenance.
If the server is absent, this field is empty.
Table 5-1. All Servers Status Information (continued)
Item Description