User's Manual
Using the CMC Web Interface 93
Warning Indicates that only warning alerts have been
issued, and corrective action must be taken
within the time frame set by the administrator.
If corrective actions are not taken within the
administrator-specified time, critical or severe
failures that can affect the integrity of the device
could occur.
Severe Indicates at least one Failure alert has been
issued. Severe status represents a system failure
on the server, and corrective action must be
taken immediately.
No Value When the server is absent from the slot, health
information is not provided.
Launch
iDRAC GUI
Left click the icon to launch the iDRAC management console
for a server in a new browser window or tab. This icon is only
displayed for a server where all of the following conditions are
true:
1
The server is present
2
The chassis power is on
3
The LAN interface on the server is enabled
NOTE: If the server is removed from the chassis, the IP address of
iDRAC is changed, or the network connection on iDRAC
experiences any problems, then clicking the Launch iDRAC GUI
icon may display an error page on the iDRAC LAN interface.
Power State Indicates the power status of the server:
•
N/A
- The CMC has not yet determined the power state of the
server.
•
Off
- Either the server is off or the chassis is off.
•
On
- Both chassis and server are on.
•
Powering On
- Temporary state between Off and On. When the
action completes successfully, the
Power State
will be
On
.
•
Powering Off
- Temporary state between On and Off. When the
action completes successfully, the
Power State
will be
Off
.
Table 5-1. All Servers Status Information (continued)
Item Description