User's Manual

Configuring CMC to Use Command Line Consoles 51
Four simultaneous SSH sessions are supported at any given time. The session
timeout is controlled by the cfgSsnMgtSshIdleTimeout property (see
the database property chapter of the Dell Chassis Management Controller
Firmware Version 2.0 Administrator Reference Guide) or from the Services
Management page in the Web interface (see "Configuring Services" on
page 139).
Enabling SSH on the CMC
SSH is enabled by default. If SSH is disabled, then you can enable it using
any other supported interface.
For instructions on enabling SSH connections on the CMC using RACADM,
see the config command section and the cfgSerial database property section
in the Dell Chassis Management Controller Firmware Version 2.0
Administrator Reference Guide. For instructions on enabling SSH connections
on the CMC using the Web interface, see "Configuring Services" on
page 139.
Changing the SSH Port
To change the SSH port, use the following command:
racadm config -g cfgRacTuning -o cfgRacTuneSshPort
<port number>
For more information about cfgSerialSshEnable and
cfgRacTuneSshPort properties, see the database property chapter of the
Dell Chassis Management Controller Firmware Version 2.0 Administrator
Reference Guide.
The CMC SSH implementation supports multiple cryptography schemes, as
shown in Table 3-2.