User's Manual

254 Power Management
Power Cycle System (cold boot)
— Powers off and then reboots the
system (cold boot). This option is disabled if the chassis is already
powered
OFF
.
NOTE: This action powers off and then reboots the entire chassis (chassis, servers
which are configured to always power on, IOMs, iKVM, and power supplies).
Reset CMC
— Resets the CMC without powering off (warm reboot).
(This option is disabled if the CMC is already powered off).
NOTE: This action only resets the CMC. No other components are affected.
Non-Graceful Shutdown
— This action forces a non-graceful power
off of the entire chassis (chassis, servers, IOMs, iKVM, and power
supplies). This does not attempt to cleanly shutdown the operating
system of the servers prior to powering off.
6
Click
Apply
. A dialog box appears requesting confirmation.
7
Click
OK
to perform the power management action (for example, cause
the system to reset).
Using RACADM
Open a serial/Telnet/SSH text console to the CMC, log in, and type:
racadm chassisaction -m chassis <action>
where
<
action
> is
powerup, powerdown, powercycle,
nongraceshutdown or reset.
Executing Power Control Operations on an IOM
You can remotely execute a reset or power cycle on an individual IOM.
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
Using the Web Interface
1
Log in to the CMC Web interface.
2
Select
I/O Modules
. The
I/O Modules Status
page displays.
3
Click the
Power Management
tab. The
Power Control
page displays.
4
Select the operation you want to execute (
reset
or
power cycle
) from the
drop-down menu beside the IOM in the list.