User's Manual

Power Management 245
Configuring Power Budget and Redundancy
The CMC’s power management service optimizes power consumption for the
entire chassis (the chassis, servers, IOMs, iKVM, CMC, and PSUs) and re-
allocates power to different modules based on the demand.
Using the Web Interface
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
1
Log in to the CMC Web interface.
2
Select
Chassis
in the system tree.
3
Click the
Power Management
tab. The
Power Budget Status
page
displays.
4
Click the
Configuration
sub-tab. The
Budget/Redundancy Configuration
page displays.
5
Set any or all of the properties described in Table 8-15 according to your
needs.
6
Click
Apply
to save your changes.
To refresh the content on the Budget/Redundancy Configuration page, click
Refresh. To print the contents, click Print.
Table 8-14. System Power Supplies
Item Description
Name Displays the name of the PSU in the format PS-n, where n, is the
PSU number.
Power State Indicates the power state of the PSU — On, Initializing, Online,
Stand By, In Diagnostics, Failed, Redundant, Unknown, or Absent
(missing).
Input Volts Displays the present input voltage of the power supply.
Input Current Displays the present input current of the power supply.
Output Rated
Power
Displays the maximum output power rating of the power supply.