152 Using the LCD Panel Interface
Error Messages If no error then "No Errors" is shown; otherwise error messages
are listed, critical errors first, then warnings.
Model Number Example "PowerEdgeM1000"
Power Consumption Current power consumption in watts
Surplus for Peak
Performance
The surplus for peak performance is computed based on the
following factors:
If server power throttling is enabled, the surplus for peak
performance value is the difference between the System
Input Power Warning Threshold and the sum of the Input
Power Allocated to Servers and the Input Power Allocated to
Chassis Infrastructure.
If server power throttling is disabled, the surplus for peak
performance value is the difference between the System
Input Power Cap and the sum of the Input Power Allocated
to Servers and the Input Power Allocated to Chassis
Infrastructure.
The value for surplus for peak performance is displayed in
watts.
Peak Power Peak power consumed in watts
Minimum Power Minimum power consumed in watts
Ambient
Temperature
Current ambient temperature in degrees Celsius
Service Tag The factory-assigned service tag
CMC redundancy
mode
Non-Redundant or Redundant
PSU redundancy
mode
Non-Redundant, AC Redundant, or DC Redundant
Table 4-11. Fan Status
Item Description
Name/Location Example: Fan1, Fan2, etc.
Table 4-10. Chassis/Enclosure Status (continued)
Item Description