Quick Reference Guide

144 Using the LCD Panel Interface
Critical CPU<number> Status: Processor
sensor for CPU<number>, IERR
was asserted
CPU failure.
Critical CPU<number> Status: Processor
sensor for CPU<number>,
thermal tripped was asserted
CPU overheated.
Critical CPU<number> Status: Processor
sensor for CPU<number>,
configuration error was asserted
Incorrect processor type or in
wrong location.
Critical CPU<number> Status: Processor
sensor for CPU<number>,
presence was de-asserted
Required CPU is missing or not
present.
Critical System Board Video Riser: Module
sensor for System Board, device
removed was asserted
Required module was removed.
Critical Mgt Riser Presence: Presence
sensor for Mgt Riser, absent was
asserted
Management Riser was removed.
Critical Backplane Presence: Presence
sensor for Backplane, absent was
asserted
Backplane was removed.
Critical System Board HeatSink Pres:
Presence sensor for System Board,
absent was asserted
Required system board heat sink
was removed.
Critical Mezz B <slot number> Status:
Add-in Card sensor for Mezz B
<slot number>, install error was
asserted
Incorrect Mezzanine card installed
for I/O fabric.
Critical Mezz B <slot number> PG:
Voltage sensor for Mezz B <slot
number>, state asserted was
asserted
No power to Mezzanine card.
Table 4-8. Server Status Screen (continued)
Severity Message Cause