Users Guide
8
Conguring storage sleds
Half-width storage sleds that are used in the FX2s chassis contain the following:
• One or two RAID controllers
• Maximum of 16 disk drives
You can congure individual storage sleds containing two RAID controllers to operate in the following modes:
• Split-single
• Split-dual
• Joined
NOTE: Do not insert a storage sled in slot 1 of the chassis as it is not a valid location for storage sleds.
NOTE: This section is applicable only to dual-controller storage modules.
NOTE: You can also congure and monitor storage sleds using the iDRAC Comprehensive Embedded Management
(CEM). For more information, see the
Integrated Dell Remote Access Controller (iDRAC) User’s Guide
.
Conguring storage sleds in split-single mode
In split-single mode, the two RAID controllers are mapped to a single compute sled. Both the controllers are enabled and each
controller is connected to eight disk drives.
Conguring storage sleds in split-dual mode
In split-dual mode, both RAID controllers in a storage sled are connected to two compute sleds.
If a storage sled is located below a full-width PowerEdge FC830 sled, it can be congured in the split-dual mode. But the controllers
are connected to a single compute sled and only that compute sled is reported.
If a storage sled is congured in the split dual mode and is in a location where it cannot be connected to two compute sleds, then the
second controller is not connected to any compute sled.
You must have the Chassis Conguration Administrator privilege and power o the compute sled before changing the setting.
Conguring storage sleds in joined mode
In joined mode, the RAID controllers are mapped to a single compute sled. However, only one controller is enabled and all the disk
drives are connected to it.
Conguring storage sleds using CMC web interface
1. In the left pane, click Chassis Overview → Server Overview and click a storage sled.
The details of the storage sled are displayed.
2. In the menu on the right side, click Setup.
The Storage Conguration page is displayed.
You can also access the Storage Conguration page by selecting a storage sled on the Chassis Health page. Under Quick
Links, click Storage Array Setup.
91