Users Guide

8
Conguring storage sleds
Half-width storage sleds that are used in the FX2s chassis contain the following:
One or two RAID controllers
Maximum of 16 disk drives
You can congure individual storage sleds containing two RAID controllers to operate in the following modes:
Split-single
Split-dual
Joined
NOTE: Do not insert a storage sled in slot 1 of the chassis as it is not a valid location for storage sleds.
NOTE: This section is applicable only to dual-controller storage modules.
NOTE: You can also congure and monitor storage sleds using the iDRAC Comprehensive Embedded Management
(CEM). For more information, see the
Integrated Dell Remote Access Controller (iDRAC) User’s Guide
.
Conguring storage sleds in split-single mode
In split-single mode, the two RAID controllers are mapped to a single compute sled. Both the controllers are enabled and each
controller is connected to eight disk drives.
Conguring storage sleds in split-dual mode
In split-dual mode, both RAID controllers in a storage sled are connected to two compute sleds.
If a storage sled is located below a full-width PowerEdge FC830 sled, it can be congured in the split-dual mode. But the controllers
are connected to a single compute sled and only that compute sled is reported.
If a storage sled is congured in the split dual mode and is in a location where it cannot be connected to two compute sleds, then the
second controller is not connected to any compute sled.
You must have the Chassis Conguration Administrator privilege and power o the compute sled before changing the setting.
Conguring storage sleds in joined mode
In joined mode, the RAID controllers are mapped to a single compute sled. However, only one controller is enabled and all the disk
drives are connected to it.
Conguring storage sleds using CMC web interface
1. In the left pane, click Chassis OverviewServer Overview and click a storage sled.
The details of the storage sled are displayed.
2. In the menu on the right side, click Setup.
The Storage Conguration page is displayed.
You can also access the Storage Conguration page by selecting a storage sled on the Chassis Health page. Under Quick
Links, click Storage Array Setup.
91