CLI Guide

idRacName - Read only
Description A user-assigned name to identify this controller.
Legal Values A string of up to 15 ASCII characters.
Default for CMC CMC
cfgLanNetworking
This group contains parameters to congure CMC NIC for IPv4.
One instance of the group is allowed. Some objects in this group may require CMC NIC to be reset, which may cause a brief loss in
connectivity. Objects that change CMC NIC IP address settings close all active user sessions and require users to reconnect using the
updated IP address settings.
For CMC, use this object with the cong or getcong subcommands.
To use this object property for CMC, you must have the Chassis Conguration Administrator privilege.
NOTE
: For CMC, you can congure a setting that does not have a hash sign (#) prexed in the output. To modify a congurable
object, use the –o option.
The following sections provide information about the objects in the cfgLanNetworking group.
cfgNicIPv4Enable - Read or Write
Description
Enables or disables the IPv4 stack.
Legal Values
1 (TRUE)
0 (FALSE)
Default
For iDRAC: 0
For CMC: 1
cfgNicVLanEnable - Read or Write
Description
Enables or disables the VLAN capabilities.
All chassis management trac, including the CMC and all iDRACs, resides on this external VLAN
when enabled. No iDRAC conguration change is required to use this external management network
VLAN.
Legal Values
1 (TRUE)
0 (FALSE)
Default 0
CMC Property Database Group and Object Descriptions 91