CLI Guide
NOTE: The Hostname and OS Name elds in the getsysinfo output display accurate
information only if Dell OpenManage Server Administrator is installed on the managed
system. Else, these elds may be blank or inaccurate. An exception to this are VMware
operating system names, which are displayed even if Server Administrator is not installed
on the managed system.
Synopsis
racadm getsysinfo [-d] [-c] [-A] [-4] [-6]
Input
• -d - Displays CMC information.
• -c - Displays chassis information.
• -A - Does not display headers and labels.
• -4 - Displays IPv4 information.
• -6 - Displays IPv6 information.
Output
CMC Information:
CMC Date/Time = Tue Jan 29 2013 23:00
CMC Location = CMC-1
Primary CMC Location = 4.40
CMC Version = 1.10
Last Firmware Update = Mon Jan 28 2013 08:41
Hardware Version = A04
CMC Network Information:
NIC Enabled = 1
MAC Address = D4:AE:52:AC:CA:C6
Register DNS CMC Name = 1
DNS CMC Name = cmc-servicetag
Current DNS Domain = swtest.com
VLAN ID = 1
VLAN Priority = 0
VLAN Enabled = 0
CMC IPv4 Information:
IPv4 Enabled = 1
Current IP Address = 192.168.164.115
Current IP Gateway = 192.168.164.1
Current IP Netmask = 255.255.255.0
DHCP Enabled = 1
Current DNS Server 1 = 192.168.165.80
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = 1
CMC IPv6 Information:
IPv6 Enabled = 0
Autoconfiguration Enabled = 1
Link Local Address = ::
Current IPv6 Address 1 = ::
Current IPv6 Gateway = ::
Current IPv6 DNS Server 1 = ::
Current IPv6 DNS Server 2 = ::
DNS Servers from DHCPv6 = 1
Chassis Information:
System Model = PowerEdge FX2s
System AssetTag = 00000
Service Tag = STPST06
Express Service Code = 62746758870
Chassis Name = CMC-STPST06
Chassis Location = [UNDEFINED]
Chassis Midplane Version = 1.0
Power Status = ON
System ID = 1488
PCIe Switch Board Type = Gen 3
NOTE
: In the Chassis Information output, the PCIe Switch Board Type information is
displayed only for PowerEdge FX2s chassis model.
RACADM Subcommand Details 57