CLI Guide
cfgKvmMapping
Description Selects the server to which the KVM connects
Legal Values
1[a-d]-4[a-d]
Default 0 (Unmapped)
cfgAlerting
This group enables or disables SNMP event trap alerting and sets the event lter.
Use this object with the cong or getcong subcommands.
cfgAlertingEnable
Description Enables or disables event traps on the CMC.
Legal Values
• 1 (true)
• 0 (false)
Default None
To use this object property, you must have the Chassis Conguration Administrator privilege.
cfgAlertingSourceEmailName
Description
Species the e-mail address used to send e-mail notications when an event occurs.
Legal Values None
Default None
Examples
racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName
racadm config -g cfgAlerting -o cfgAlertingSourceEmailName user@home.com
Object value modified successfully.
To use this object property, you must have Chassis Conguration Administrator and Test Alert User privileges.
cfgIPv6LanNetworking
This group is used to congure the IPv6 over LAN networking capabilities.
Use this object with the cong or getcong subcommands.
CMC Property Database Group and Object Descriptions
135