Resolution: When in split-dual host mode, each host that is connected to the storage sled RAID must be power cycled for
the RAID firmware change to be effective.
Problem: PCIe slot reassignment option is disabled in the GUI.
Resolution: Ensure that all hosts in the chassis are powered on. If you attempt changing this setting from RACADM while a
host is powered on, an error message is displayed. The chassis configuration administrator privilege is required to change this
setting.
Problem: PCIe slot reassignment enabled and host is powered on, but the PCIe slots are not powered on.
Resolution: Check the Chassis Log for warning messages associated with outdated BIOS, iDRAC, or unsupported host.
Problem: Not able to import, export, or delete storage module licenses.
Resolution: Chassis configuration privilege is required to import, export, and delete storage module licenses.
Resetting Forgotten Administrator Password
CAUTION: Many repairs may only be done by a certified service technician. Perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and
follow the safety instructions that came with the product.
To perform management actions, a user with Administrator privileges is required. The CMC software has a user account
password protection security feature that may be disabled if the administrator account password is forgotten. If the
administrator account password is forgotten, it can be recovered using the J_PWORD jumper on the CMC board.
The CMC board has a two-pin password reset connector as shown in the following figure. If a jumper is installed in the reset
connector, the default administrator account and password is enabled and set to the default values of username: root and
password: calvin. The administrator account is reset regardless if the account has been removed, or if the password was
changed.
NOTE: Make sure that the CMC module is in a passive state before you begin.
To perform management actions, a user with Administrator privileges is required. If the administrator account password is
forgotten, it can be reset using the J_PWORD jumper on the CMC board.
The J_PWORD jumper uses a two-pin connector as shown in the following figure.
While the J_PWORD jumper is installed, the default administrator account and password is enabled and set to the following
default values:
username: root
password: calvin
The administrator account is temporarily reset regardless if the administrator account was removed, or if the password was
changed.
NOTE:
When the J_PWORD jumper is installed, a default serial console configuration is used (rather than configuration
property values), as follows:
cfgSerialBaudRate=115200
cfgSerialConsoleEnable=1
cfgSerialConsoleQuitKey=^\
cfgSerialConsoleIdleTimeout=0
cfgSerialConsoleNoAuth=0
cfgSerialConsoleCommand=""
cfgSerialConsoleColumns=0
1. Press the CMC release latch on the handle and pull the module front panel. Slide the CMC module out of the enclosure.
154
Troubleshooting and recovery