Users Guide

Table Of Contents
System Shutting Down"
# If power was restored before the shutdown kicked in,
cancel it.
pr:12345:powerokwait:/sbin/shutdown -c "Power
Restored; Shutdown Cancelled"
# Run gettys in standard runlevels
co:2345:respawn:/sbin/agetty -h -L 57600 ttyS1 ansi
1:2345:respawn:/sbin/mingetty tty1
2:2345:respawn:/sbin/mingetty tty2
3:2345:respawn:/sbin/mingetty tty3
4:2345:respawn:/sbin/mingetty tty4
5:2345:respawn:/sbin/mingetty tty5
6:2345:respawn:/sbin/mingetty tty6
# Run xdm in runlevel 5
# xdm is now a separate service
x:5:respawn:/etc/X11/prefdm -nodaemon
Edit the /etc/securettyfile as follows:
Add a new line, with the name of the serial tty for COM2:
ttyS1
The following example shows a sample file with the new line.
vc/1
vc/2
vc/3
vc/4
vc/5
vc/6
vc/7
vc/8
vc/9
vc/10
vc/11
tty1
tty2
tty3
tty4
tty5
tty6
tty7
tty8
tty9
tty10
tty11
ttyS1
Managing CMC using iDRAC RACADM proxy
CMC can be managed using iDRAC RACADM proxy when CMC is not on the network. The following table lists the mapping of
CMC privileges with iDRAC privileges for the proxy operation.
Table 24. CMC-iDRAC privileges mapping
CMC Privilege iDRAC privilege required for proxy operation
CMC Login User iDRAC Login
Chassis Configuration Administrator Configure iDRAC
User Configuration Administrator Configure Users in iDRAC
Clear Logs Administrator Logs
Chassis Control Administrator System Control
Configuring CMC to use Command Line consoles 117