Known Issues
Issue 1:
Description
PCIe card device name displayed on the iDRAC GUI and CMC GUI are not same for Broadcom/Qlogic 10G
card.
Resolution
Refer to the iDRAC GUI, it is accurate and current.
Versions/Systems Affected
None
Issue 2:
Description
An error occurs while importing CMC configuration file using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the configuration file. Enable or disable IPv6 using
the command “racadm config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0”.
Versions/Systems Affected
CMC for PowerEdge FX2 1.10 or later
Limitations
Issue 1:
Description
In the Microsoft Edge browser, the Boot Identity Profiles page in the CMC GUI is slow when 1500 or more
MAC addresses are created from the MAC pool for the Boot Identity profile.
Resolution
Create less than 1500 MAC address in the Microsoft Edge browser. Use other supported browsers for more
than 1500 MAC addresses.
Versions/Systems Affected
CMC for PowerEdge FX2 1.40 or later
Issue 2:
Description
Racresetcfg does not work when the six RSA-4096 or four RSA-2048, and two 2048 DSA SSH public keys
are uploaded to the CMC.
Resolution
Do not upload six RSA-4096 or four RSA-2048, and two 2048 DSA SSH public keys to the CMC.
Versions/Systems Affected
CMC for PowerEdge FX2 1.10 or later