Reference Guide
< slot# > = 1 to 4
< fabricName > = A1 or A2
< state > = 0 or 1
where 0 is disable and 1 is enable.
Input
• -i <slot#> <state> — Enables or disables FlexAddress for the specied slot.
• -f <fabricName> <state> — Enables or disables FlexAddress for the specied fabric.
Example
• racadm setflexaddr -i 1 0
Slot 1 FlexAddress state set successfully
• racadm setflexaddr -f A 1
Fabric A FlexAddress state set successfully
• racadm setflexaddr -f idrac 1
setled
Description Sets the state (blinking or not blinking) of the LED on the specied module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug
Administrator privilege on CMC. To enable the servers to blink or unblink, you must have the
Server Administrator or Debug Administrator privilege on CMC.
Synopsis
racadm setled -m <module> -l <ledState>
Input
• -m<module> — Species the module whose LED you want to congure.
<module> can be one of the following:
— server-n, where n=1–4
— switch-n, where n=1–2
— cmc-active
— chassis
•
-l<ledstate> — Species whether the LED should blink.
<ledstate> can be one of the following:
– 0 — no blinking
– 1 — blinking
Example
• racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of a
multi-slot server.
• racadm setled -m server-2 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
75