Reference Guide

gettracelog
Description Lists all the trace log entries in CMC.
Synopsis
racadm gettracelog -i [-A]
racadm gettracelog [-s <start>] [-c <count>] [--more] [-A] [-o]
Input
-i - Displays the number of entries in CMC trace log.
--more - Displays one screen at a time and prompts the user to continue (similar to the UNIX
more command).
-o - Displays each entry in a single line.
-c - Species the number of records to display.
-s - Species the starting record to display.
-A - Does not display headers or labels.
NOTE: The -A and -o options are deprecated.
Output The default output display shows the record number, timestamp, source, and description. The
timestamp begins at midnight, January 1 and increases until the system boots. After the system
boots, the systems timestamp is used.
Example
Record: 1
Date/Time: Dec 8 08:21:30
Source: ssnmgrd[175]
Description: root from 192.68.157.103: session timeout
sid 0be0aef4
getversion
Description
Displays the current software version, model and generation information, and whether the target
device can be updated.
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getversion
racadm getversion [-b | -c] [-m <module>]
racadm getversion -l [-m <module>] [-f <filter>]
Input
NOTE: The -b, -c and -l options are not available for CMC modules.
NOTE: The -l option requires that the Lifecycle Controller service is enabled on the
servers. For version information, see the RACADM Readme available at dell.com/
support/manuals.
(none) — Displays the version information for all targets or devices.
<Server> <iDRAC Version> <Blade Type>
<Gen> <Updatable>
server-1a 2.15.15.15 (18) PowerEdge FC430
iDRAC8 Y
server-1b 2.40.40.40 (13) PowerEdge FC430
iDRAC8 Y
server-1c 2.10.10.10 (49) PowerEdge FC430
iDRAC8 Y
57