Reference Guide
• racadm getstoragemoduleinfo <FQDD>
Input -c — The -c <FQDD> option can be used to view the details of a storage sled. The availability of
this option is based on the <FQDD> input. This command is supported only when a storage sled
is present in the CMC FX2/FX2s chassis.
Examples
racadm getstoragemoduleinfo
<Storage Slot> <FQDD>
Storage-1 N/A
Storage-2 System.Modular.02
Storage-3 System.Modular.03
Storage-4 System.Modular.04
Display format of storage sled information when the storage mode is “joined” or has a single
controller.
racadm getstoragemoduleinfo -c System.Modular.02
Storage-2 FQDD = System.Modular.02
Chassis Slot = 2
Name = SLOT-02
Model = PowerEdge FD332
Status = Not OK
Service Tag = 2435678
Asset Tag = ABCD12345
Intrusion State = Open
Storage Mode = Joined
Number of Controllers = 1
FQDD = RAID.Modular.2-1
Physical Disk Slots = 0-15
Connected Server = SLOT-01
Controller Mode Capability = HBA and RAID
Display format of storage sled information when the storage mode is “split single host”.
racadm getstoragemoduleinfo -c System.Modular.03
Storage-2 FQDD = System.Modular.03
Chassis Slot = 3
Name = SLOT-03
Model = PowerEdge FD332
Status = Not OK
Service Tag = 8748596
Asset Tag = KLOP98656
Intrusion State = Closed
Storage Mode = Split single host
Number of Controllers = 2
FQDD = RAID.Modular.3-1
Physical Disk Slots = 0-7
Connected Server = SLOT-01
Controller Mode Capability = HBA
FQDD = RAID.Modular.3-2
Physical Disk Slots = 8-15
Connected Server = SLOT-1
Controller Mode Capability = HBA
Display format of storage sled information when the storage mode is “Split dual host”.
racadm getstoragemoduleinfo -c System.Modular.03
Storage-3 FQDD = System.Modular.03
Chassis Slot = 3
54