Reference Guide

<IO> <Name> <Type>
<Presenc
e> <POST> <Power> <Role>
<SecureM
ode> <Mode>
Switch-
1
1GBE PASS-
THROUGH
MODULE
Gigabit
Ethernet
Present OK ON Master No N/A
getled
Description Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).
To use this subcommand, you must have the Login User privilege.
Synopsis
racadm getled -m <module>
Input CMC only options:
-m < module > — Species the module whose LED settings you want to view.
< module > can be one of the following:
server-n where n=1 or 4
switch-n where n=1 or 2
chassis
CMC active
Example For CMC:
racadm getled -m server-4
<module> <LED state> server-4 Blinking
racadm getled -m chassis
<module> <LED state> server-4 Not blinking
racadm getled -m server-1
<module> <LED state> server-1 ON
racadm getled -m server-1
<module> <LED state> server-1 Extension(1)
getmacaddress
Description
Displays the MAC/WWN addresses for all modules or for a specied module.
The decoder values in the Type column indicate the protocols of the network cards.
0— Unsupported
1— ISCSI
2— FCoE-FIP
3— iSCSI/FCoE-FIP
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getmacaddress
racadm getmacaddress -m chassis
racadm getmacaddress -m switch-<n>
racadm getmacaddress [-m <module>] [-t iscsi] [-x]
racadm getmacaddress [-a]
38