Reference Guide

cfgRacSecCsrKeySize (Read/Write)
Description Species the SSL asymmetric key size for the CSRs.
Legal Values 1024, 2048, 4096
Default 2048
cfgPCIe
Displays the PCIe reassignment information.
Use this sub command with the getconfig and config commands.
The following section provides information about the objects in the cfgPCIe group.
cfgPCIeReassignmentEnable (Read/Write)
Description
Indicates whether the PCIe reassignment is enabled or disabled.
Legal Values
0 — Disable
1 — Enable
NOTE: Power o all the servers in the FX2s chassis before changing the PCIe reassignment.
cfgQuickDeploy
This group is used to congure IDRAC deployment settings. You must have blade administrator privileges for conguring the settings.
cfgActionOnServerInsertion
Table 4. cfgActionOnServerInsertion — Details
Description
Congures settings when a new server is inserted into the slot.
Legal Values
0 — No Action
1 — QuickDeploy Only
2 — Server Prole Only
3 — Quick Deploy and Server Prole
Default
0
cfgSetiDRACRootPasswordOnServerInsertion
Table 5. cfgSetiDRACRootPasswordOnServerInsertion — Details
Description
Sets the iDRAC root password when a server is inserted into the chassis.
Legal Values
0 (False) — If the value is ‘1’ when the server is inserted, the iDRAC root
password is not set.
1 (True) — If the value is ‘1’ when the server is inserted, the iDRAC root
password is set.
138