Reference Guide
Default 0 (Unmapped)
cfgAlerting
This group enables or disables SNMP event trap alerting and sets the event lter.
Use this object with the cong or getcong subcommands.
cfgAlertingEnable
Description Enables or disables event traps on the CMC.
Legal Values
• 1 (true)
• 0 (false)
Default None
To use this object property, you must have the Chassis Conguration Administrator privilege.
cfgAlertingSourceEmailName
Description Species the e-mail address used to send e-mail notications when an event occurs.
Legal Values None
Default None
Examples
racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName
racadm config -g cfgAlerting -o cfgAlertingSourceEmailName user@home.com
Object value modified successfully.
To use this object property, you must have Chassis Conguration Administrator and Test Alert User privileges.
cfgIPv6LanNetworking
This group is used to congure the IPv6 over LAN networking capabilities.
Use this object with the cong or getcong subcommands.
To use this object property for CMC, you must have Chassis Conguration Administrator privilege.
NOTE: To apply this setting to iDRAC, use the -m option.
The following sections provide information about the objects in the cfgIPv6LanNetworking group.
129