Connectivity Guide
2. The power supply unit is operating normally
3. The power supply unit has encountered a hardware problem or is not
responding
4. The power supply unit is no longer connected to the enclosure or there
exists a problem communicating to it
5. The power supply unit is unstable
Syntax INTEGER
Access read-only
Table 350. Enclosure Power Supply Part Number
Name
enclosurePowerSupplyPartNumber
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7
Description The part number of the power supply unit.
Syntax DisplayString
Access read-only
Table 351. Enclosure Power Supply Component Status
Name
enclosurePowerSupplyComponentStatus
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.9
Description The status of the power supply unit itself without the propagation of any
contained component status. Possible values:
1. Other
2. Unknown
3. OK
4. Non-critical
5. Critical
6. Non-recoverable
Syntax ObjectStatusEnum
Access read-only
Table 352. Enclosure Power Supply FQDD
Name
enclosurePowerSupplyFQDD
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15
Description The power supply unit's Fully Qualied Device Descriptor (FQDD) as represented
in Storage Management.
Syntax FQDDString
Access read-only
Table 353. Enclosure Power Supply Display Name
Name
enclosurePowerSupplyDisplayName
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.16
Description The power supply unit's friendly FQDD as represented in Storage Management.
Syntax DisplayString
89