Connectivity Guide
Table 125. PowerEdge M1000e CMC traps
TrapID Name Description Severity Category
2000 alertCMCTestTrap CMC has generated a test trap. Informational Error Events
2002 alertCMCNormalTrap CMC reported a return-to-
normal or informational event.
Normal Error Events
2003 alertCMCWarningTrap CMC reported a warning event. Warning Error Events
2004 alertCMCCriticalTrap CMC reported a critical event. Critical Error Events
2005 alertCMCNonRecoverable
Trap
CMC reported a catastrophic
event.
Non-Recoverable Error Events
PowerEdge VRTX CMC Traps and PowerEdge FX2 CMC Traps
This section denes the traps that are generated by the SNMP agent of the PowerEdge VRTX CMC and PowerEdge FX2 CMC. All
of the enterprise-specic traps documented in this section belong to the MIB enterprise identied by OID 1.3.6.1.4.1.674.10892.2.21
and are sent with the following trap variables: drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus,
drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag and drsGlobalCurrStatus. The trap
variables are dened in the Dell Remote Access Controller Out-of-Band Group section.
System Trap Group
The System Trap Group contains traps that fall under the System event category.
Table 126. Amperage Probe Traps
TrapID Description Category SubCategory Severity
alert2AmperageProbeNormal
2179 Current sensor reading is within
range.
Status Events Amperage Informational
alert2AmperageProbeWarning
2178 Current sensor has detected a
warning value.
Status Events Amperage Minor
alert2AmperageProbeFailure
2177 Current sensor has detected a
failure value.
Error Events Amperage Critical
Table 127. Battery Traps
TrapID Description Category SubCategory Severity
alert2BatteryNormal
2227 Battery state has returned to
normal; or battery presence had
been detected.
Status Events Battery Informational
alert2BatteryWarning
2226 Battery is low. Status Events Battery Minor
alert2BatteryFailure
36