Connectivity Guide

Table 90. DRsPSUVoltsReading
Name
drsPSUVoltsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.5
Description Denes the instantaneous PSU voltage reading.
Syntax DellPowerReading
Access Read-only
Table 91. DRsPSUAmpsReading
Name
drsPSUAmpsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6
Description Denes the instantaneous PSU current reading.
Syntax DellPowerReading
Access Read-only
Table 92. DRsPSUWattsReading
Name
drsPSUWattsReading
Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7
Description Denes the instantaneous PSU wattage reading.
Syntax DellPowerReading
Access Read-only
Chassis Servers
The following MIB tables provide server information for the chassis being monitored by the chassis management controller.
Table 93. DRsCMCServerTable
Name
drsCMCServerTable
Object ID 1.3.6.1.4.1.674.10892.2.5.1
Description Denes the CMC server table.
Syntax SEQUENCE OF DrsCMCServerTableEntry
Access Not-Accessible
Table 94. DRsCMCServerTableEntry
Name
drsCMCServerTableEntry
Object ID 1.3.6.1.4.1.674.10892.2.5.1.1
Description Denes the CMC server table entry.
Syntax DrsCMCServerTableEntry
Access Not-Accessible
CMC Server Information
The following MIB tables provide CMC server information being monitored by the chassis management controller.
24