Reference Guide
cfgChassisRedundancyPolicy (Read/Write)
Description Sets the redundancy policy of the chassis.
Legal Values
• 0 (no redundancy)
• 1 (AC redundancy)
• 2 (power supply redundancy)
Default 0 (no redundancy)
cfgChassisDynamicPSUEngagementEnable (Read/Write)
Description Enables or disables dynamic engagement.
Legal Values
• 0 (disabled)
• 1 (enabled)
Default 0 (disabled)
cfgChassisInMaxPowerCapacity (Read Only)
Description Indicates the total chassis power budget (in watts) available for chassis operation.
Legal Values None
Default None
cfgChassisInRedundancyReserve (Read Only)
Description Indicates the amount of redundant power (in Watt) in reserve that can be utilized in
the event of an AC grid or PSU failure. This value is 0 if the Redundancy Policy is set to
0 (no redundancy).
Legal Values 0 (disabled)
1 (enabled)
Default None
cfgChassisInPowerServerAllocation (Read Only)
Description Indicates (in Watt) the cumulative power allocated to servers. There is no default as
this parameter is very specific to the particular customer configuration.
Legal Values None
Default None
cfgChassisInfrastructureInPowerAllocation (Read Only)
Description
Indicates the estimated cumulative DC output power consumption (in watts),
determined from a field replaceable unit (FRU) on the hardware modules in the chassis.
Legal Values None
138