Quick Reference Guide
• racadm setflexaddr -f A 1
Fabric A FlexAddress state set successfully
• racadm setflexaddr -f idrac 1
setled
Description Sets the state (blinking or not blinking) of the LED on the specified module.
To blink or unblink the chassis, I/O modules or the CMC, you must have the Debug Administrator
privilege on CMC. To enable the servers to blink or unblink, you must have the Server
Administrator or Debug Administrator privilege on CMC.
Synopsis
racadm setled -m <module> -l <ledState>
Input
• -m <
module
> - Specifies the module whose LED you want to configure.
<
module
> can be one of the following:
— server-n, where
n
=1–4
— switch-n, where n=1
— cmc-active
— chassis
• -l <
ledstate
> - Specifies whether the LED should blink.
<
ledstate
> can be one of the following:
– 0 — no blinking
– 1 — blinking
Example
• racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of a
multi-slot server.
• racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
setniccfg
Description Sets the iDRAC IP address. It displays an error message if the requested operation
could not be performed, or a success message, if the operation is completed
successfully.
To use this subcommand, you must have the Configure iDRAC privilege.
NOTE: The terms NIC and Ethernet management port may be used
interchangeably.
Synopsis
• racadm setniccfg -d
• racadm setniccfg -d6
• racadm setniccfg -s <IPv4Address> <netmask> <IPv4
gateway>
84