Quick Reference Guide
NOTE: The -A and -o options are deprecated.
Output The default output display shows the record number, timestamp, source, and description. The
timestamp begins at midnight, January 1 and increases until the system boots. After the system
boots, the system’s timestamp is used.
Example
Record: 1
Date/Time: Dec 8 08:21:30
Source: ssnmgrd[175]
Description: root from 143.166.157.103: session timeout
sid 0be0aef4
getversion
Description
Displays the current firmware version of various modules in the chassis, iDRAC version on the
attached servers, and whether the target device can be updated.
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
• racadm getversion
• racadm getversion [-b | -c] [-m <module>]
• racadm getversion -l [-m <module>] [-f <filter>]
Input
NOTE: The -b, -c and -l options are not available for CMC modules.
NOTE: The -l option requires that the Lifecycle Controller service is enabled on the servers. For
version information, see the RACADM Readme available at dell.com/support/manuals.
• (none) — Displays the version information for all targets or devices.
<Server> <iDRAC Version> <Blade Type> <Gen>
<
Updatable>
server-4 1.30.30 (Build 26) PowerEdge M620
iDRAC7 Y
<Server> <CMC Version> <Updatable>
cmc-1 1.00.X23.201211271524 Y
<Chassis Infrastructure> <FW Version> <FQDD>
Main Board 1.00.X08.201210242214
System.Chassis.1#Infrastructure.1
<Storage Controller> <FW Version> <FQDD>
PERC H710PV Mini 23.8.0-0007
RAID.ChassisIntegrated.1-1
<Storage Enclosure> <FW Version> <FQDD>
PL100 0:0 0.12
Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
<Physical Disk> <FW Version> <FQDD>
Physical Disk 0:0:0 ES65 Disk.Bay.
0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
• -b - Displays the server's current BIOS version (default is iDRAC version).
• -c - Displays the server's current CPLD version.
56