Reference Guide
— powerdown — Turns o the managed system.
— powerup — Turns on the managed system.
— powerstatus — Displays the current power status of the server (ON or OFF).
— reseat — Performs a virtual reseat of the server. This operation simulates reseating the
server by resettig the iDRAC on a server.
NOTE: The reseat option is not available for individual FM120 servers.
NOTE: The action powerstatus is not allowed with an -a option.
Output Displays an error message if the requested operation fails, or a success message if the operation
is completed.
Example
• Turn o server 3 from the CMC
racadm serveraction -m server-3 powerdown
Server power operation successful
• Turn o server 3 from iDRAC
racadm serveraction powerdown
Server power operation successful
• Turn o server 3 from CMC when Power is already turned o on that server
racadm serveraction -m server-3 powerdown
Server is already powered OFF.
• Turn o the server from CMC when Power is already turned o on that server.
racadm serveraction powerdown
Server is already powered OFF
• Get Power Status of server 2 on CMC
racadm serveraction -m server-2 powerstatus
ON
• Get Power status action on multinode server:
racadm serveraction -m server-1a powerstatus
• Get Power Status on iDRAC
racadm serveraction powerstatus
Server Power Status: ON
• Reseat action on a multinode sled
racadm serveraction -f -m sled-1 reseat
• Explanation of Support
CMC needs to support graceful shutdown
The support of address individual blades is expected on the CMC
set
Description
Import saved CMC conguration or CMC Event Filter conguration from a le.
69